Specimen set 1: Paper 3B Medical physics

35 marks · 13 question parts · Paper, mark scheme and report on AQA's site · Have the data and formulae booklet beside you

Question by question

QTopicMarksAOType
1.1 Physics of the eye, the ear and the ECG 2Short answer
1.2 Physics of the eye, the ear and the ECG 2Diagram or graph
1.3 Physics of the eye, the ear and the ECG 1Short answer
1.4 Physics of the eye, the ear and the ECG 2Calculation
1.5 Physics of the eye, the ear and the ECG 2Short answer
2.1 Physics of the eye, the ear and the ECG 2Short answer
2.2 Physics of the eye, the ear and the ECG 3Explanation
2.3 Physics of the eye, the ear and the ECG 3Calculation
2.4 Physics of the eye, the ear and the ECG 2Calculation
3 Medical imaging: ultrasound, X-rays, CT, MRI and radionuclides 6Extended response
4.1 Medical imaging: ultrasound, X-rays, CT, MRI and radionuclides 2Explanation
4.2 Medical imaging: ultrasound, X-rays, CT, MRI and radionuclides 4Calculation
4.3 Medical imaging: ultrasound, X-rays, CT, MRI and radionuclides 4Explanation

The questions

1.11.21.31.41.52.12.22.32.434.14.24.3
Specimen set 1 · Paper 3B Medical physics · Q1.1 2 marks Short answer eye ear and ecg
State what is meant by the principal focus and the power of a converging lens.
[2 marks]
Specimen set 1 · Paper 3B Medical physics · Q1.2 2 marks Diagram or graph eye ear and ecg
Earlier part of question 1 that this part usesEarlier part of Specimen set 1 Paper 3B Medical physics question 1
Complete the ray diagram below to show the formation of an image of a real object O
by a diverging lens. Label the image clearly.
[2 marks]
Specimen set 1 · Paper 3B Medical physics · Q1.3 1 mark Short answer eye ear and ecg
Earlier part of question 1 that this part usesEarlier part of Specimen set 1 Paper 3B Medical physics question 1
State the defect of vision that would be corrected using a diverging lens.
[1 mark]
Specimen set 1 · Paper 3B Medical physics · Q1.4 2 marks Calculation eye ear and ecg
Earlier part of question 1 that this part usesEarlier part of Specimen set 1 Paper 3B Medical physics question 1
A diverging lens of focal length −0.33 m is used to view a real object placed 0.25 m
from the lens.
Calculate the distance from the lens to the image.
[2 marks]
distance from lens to image =  m
Specimen set 1 · Paper 3B Medical physics · Q1.5 2 marks Short answer eye ear and ecg
Earlier part of question 1 that this part usesEarlier part of Specimen set 1 Paper 3B Medical physics question 1
Two point sources of light are viewed by a normal eye and their images are formed at
the fovea.
State, in terms of the active receptors, the conditions necessary for two separate
images to be seen.
[2 marks]
Specimen set 1 · Paper 3B Medical physics · Q2.1 2 marks Short answer eye ear and ecg
Sound waves are incident on a human ear.
Describe how the frequency and amplitude of the vibrations change as the wave is
transmitted through the ear to the fluid in the inner ear.
[2 marks]
Specimen set 1 · Paper 3B Medical physics · Q2.2 3 marks Explanation eye ear and ecg
Earlier part of question 2 that this part usesEarlier part of Specimen set 1 Paper 3B Medical physics question 2
Explain how the components of the ear act to amplify the pressure changes due to the
sound wave.
[3 marks]
Specimen set 1 · Paper 3B Medical physics · Q2.3 3 marks Calculation eye ear and ecg
Earlier part of question 2 that this part usesEarlier part of Specimen set 1 Paper 3B Medical physics question 2
A sound intensity meter, set to the dB scale, is placed near to a source of sound.  The
intensity level reading on the sound meter is 82 dB.
Calculate in, W m−2, the intensity of the sound at the meter.
[3 marks]
intensity =  W m−2
Specimen set 1 · Paper 3B Medical physics · Q2.4 2 marks Calculation eye ear and ecg
Earlier part of question 2 that this part usesEarlier part of Specimen set 1 Paper 3B Medical physics question 2
The sound intensity meter is 2.0 m from the source which is emitting sound equally in
all directions.
Calculate the power emitted by the source.
[2 marks]
power =   W
Specimen set 1 · Paper 3B Medical physics · Q3 6 marks 6-mark extended response medical imaging
Positron Emission Tomography (PET) and ultrasound scans are both used in medical
diagnosis.  Compare the quality of the information obtained from these scans in terms
of:
•
patient safety and convenience
•
information available to the doctor from the images.
[6 marks]
Specimen set 1 · Paper 3B Medical physics · Q4.1 2 marks Explanation medical imaging
Explain why the effective half-life of a radionuclide in a biological system is always less
than the physical half-life.
[2 marks]
Specimen set 1 · Paper 3B Medical physics · Q4.2 4 marks Calculation medical imaging
Earlier part of question 4 that this part usesEarlier part of Specimen set 1 Paper 3B Medical physics question 4
The physical half-life of a radionuclide is 20 days.  The nuclide was administered to a
patient.  Initially the corrected count rate at the patient’s body was 2700 counts s−1.
Five days later, the corrected count rate at the same place on the patient was
1200 counts s−1.
Calculate the biological half-life of the nuclide.
[4 marks]
biological half-life =  days
Specimen set 1 · Paper 3B Medical physics · Q4.3 4 marks Explanation medical imaging
Earlier part of question 4 that this part usesEarlier part of Specimen set 1 Paper 3B Medical physics question 4
Table 1 gives the properties of two radionuclides.
Table 1
Technetium 99 m
Iodine 131
emitted radiation
gamma
beta− and gamma
half-life / hours
6.0
190
energy of gamma ray / keV
140
610
By considering information in Table 1 suggest which of these nuclides is more
suitable for use as a tracer in medical diagnosis.
[4 marks]

Work with an AQA physics tutor

Want a paper marked and gone through with you? Message us.

Prefer email? Send an enquiry

If you are under 18, please include a parent's contact details. Enquiries go to enquiries@physicsaleveltutor.com and are deleted once handled. All tutoring is online.